男总裁被保镖c呻吟双腿大张bl,扒开学生双腿猛进入喷水小说,狠狠躁18三区二区一区,日本边添边摸边做边爱60分钟

北京祥生興業科技有限公司

中級會員·8年

聯系電話

13681184382

當前位置:> 供求商機> 類固醇激素校準品

類固醇激素校準品
類固醇激素校準品

更新時間:2024/12/25 21:00:08

訪問次數:272

聯系我們時請說明是化工儀器網上看到的信息,謝謝!
分享
中級會員·8年
人:
張先生
話:
13681184382
機:
13681184382
址:
北京市北京經濟技術開發區同濟中路甲7號18幢A座1010
化:
www.xiangshengbio.com
址:

掃一掃訪問手機商鋪

供應簡介
供應商:祥生興業規格:7x3ml(lyoph


詳細介紹

溫馨提示:僅用于科研,不可用于臨床治療

  • 供應商:

    祥生興業

  • 規格:

    7 x 3 ml (lyoph.)


    72038  6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1


    Order no.: 72038
    • 11-Deoxycortisol
    • 21-Deoxycortisol
    • Aldosterone
    • Corticosterone
    • Cortisol
    • Cortisone

    MassChrom® Steroids in Serum/Plasma - LC-MS/MS

    DESCRIPTION

    6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1, lyophilised
    For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.

    These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 1 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
    These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

    TECHNICAL DATA

    Method of Analysis

    LC-MS/MS

    Content

    7 x 3 ml (lyoph.)

    Parameter

    11-Deoxycortisol, 21-Deoxycortisol, Aldosterone, Corticosterone, Cortisol, Cortisone

    Concentrations

    Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

    Substance  Unit Calibrator 1 Calibrator 2 Calibrator 3 Calibrator 4 Calibrator 5 Calibrator 6 Blank Calibrator
    Aldosterone µg/l 0.024 0.084 0.161 0.319 0.816 4.23 n.d. (< 0.014)
    Corticosterone µg/l 0.455 0.997 2.39 4.86 14.9 48.1 n.d. (< 0.175)
    Cortisol µg/l 9.02 20.1 39.1 77.5 149 290 n.d. (< 1.52)
    Cortisone µg/l 0.942 2.56 4.93 9.66 19.5 38.8 n.d. (< 0.148)
    11-Deoxycortisol µg/l 0.088 0.484 0.938 1.87 4.66 13.7 n.d. (< 0.030)
    21-Deoxycortisol µg/l 0.070 0.163 0.257 0.513 1.56 4.69 n.d. (< 0.027)
     
    n.d. = not determined, analytes under LOQ

    Reconstitution

    Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.

    Storage conditions

    Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

     

    72039  6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2


    Order no.: 72039
    • 11-Deoxycorticosterone
    • 17-OH-progesterone
    • Androstenedione
    • Dehydroepiandrosterone (DHEA)
    • Dehydroepiandrosterone sulfate (DHEA-S)
    • Dihydrotestosterone (DHT)
    • Estradiol
    • Progesterone
    • Testosterone

    MassChrom® Steroids in Serum/Plasma - LC-MS/MS

    DESCRIPTION

    6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2, lyophilised
    For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.

    These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 2 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
    These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

    TECHNICAL DATA

    Method of Analysis

    LC-MS/MS

    Content

    7 x 3 ml (lyoph.)

    Parameter

    11-Deoxycorticosterone, 17-OH-progesterone, Androstenedione, Dehydroepiandrosterone (DHEA), Dehydroepiandrosterone sulfate (DHEA-S), Dihydrotestosterone (DHT), Estradiol, Progesterone, Testosterone

    Concentrations

    Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

    Substance  Unit Calibrator 1 Calibrator 2 Calibrator 3 Calibrator 4 Calibrator 5 Calibrator 6 Blank Calibrator
    Androstenedione µg/l 0.202 0.408 0.820 1.54 5.09 15.3 n.d. (< 0.020)
    11-Deoxycorticosterone µg/l 0.049 0.098 0.146 0.288 0.721 2.80 n.d. (< 0.023)
    DHEA µg/l 1.04 5.25 10.3 15.6 30.7 60.7 n.d. (< 0.229)
    DHEAS µg/l 117 558 1097 2066 3949 5887 n.d. (< 24.4)
    Dihydrotestosterone µg/l 0.061 0.111 0.257 0.501 0.942 1.50 n.d. (< 0.042)
    Estradiol µg/l 0.043 0.105 0.260 0.530 1.59

    5.33

    n.d. (< 0.026)
    17-Hydroxyprogesterone µg/l 0.097 0.498 1.01 2.00 3.98 15.0 n.d. (< 0.040)
    Progesterone µg/l 0.180 0.805 2.11 5.27 10.3 26.0 n.d. (< 0.030)
    Testosterone µg/l 0.055 0.250 0.982 2.94 5.82 11.6 n.d. (< 0.005)
     n.d. = not determined (< LOQ)

    Reconstitution

    Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.

    Storage conditions

    Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

     

溫馨提示:不可用于臨床治療。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~
產品對比 二維碼 在線交流

掃一掃訪問手機商鋪

對比框

在線留言
主站蜘蛛池模板: 个旧市| 五华县| 卓尼县| 崇文区| 新建县| 桂平市| 古浪县| 平顶山市| 青河县| 读书| 宁海县| 建湖县| 竹溪县| 胶南市| 万年县| 新密市| 兰考县| 太原市| 怀安县| 塔城市| 边坝县| 从化市| 铜鼓县| 新巴尔虎右旗| 岚皋县| 万盛区| 新乡市| 依安县| 车致| 大邑县| 江山市| 特克斯县| 大竹县| 嘉善县| 金沙县| 天长市| 碌曲县| 明水县| 开阳县| 巢湖市| 连州市|